The VM-Series firewall is distributed using the Open Virtualization Alliance (OVA) format, which is a standard method of packaging and deploying virtual machines. You can install this solution on any x86 device that is capable of running VMware ESXi.
In order to deploy a VM-Series firewall, you must be familiar with VMware and vSphere including vSphere networking, ESXi host setup and configuration, and virtual machine guest deployment.
You can deploy one or more instances of the VM-Series firewall on the ESXi server. Where you place the VM-Series firewall on the network depends on your topology. Choose from the following options (for environments that are not using VMware NSX):
You can create and deploy multiple instances of the VM-Series firewall on an ESXi server. Because each instance of the firewall requires a minimum resource allocation number of CPUs, memory and disk space—on the ESXi server, make sure to conform to the specifications below to ensure optimal performance.
The VM-Series firewall has the following requirements:
The host CPU must be a x86-based Intel or AMD CPU with virtualization extension.
VMware ESXi with vSphere 5.1, 5.5, 6.0, or 6.5 for VM-Series running PAN-OS 8.0. The VM-Series firewall on ESXi is deployed with VMware virtual machine hardware version 9 (vmx-09); no other VMware virtual machine hardware versions are supported.
See VM-Series System Requirements for the minimum hardware requirements for your VM-Series model.
Minimum of two network interfaces (vmNICs). One will be a dedicated vmNIC for the management interface and one for the data interface. You can then add up to eight more vmNICs for data traffic. For additional interfaces, use VLAN Guest Tagging (VGT) on the ESXi server or configure subinterfaces on the firewall.
The use of hypervisor assigned MAC address is enabled by default. vSphere assigns a unique vmNIC MAC address to each dataplane interface of the VM-Series firewall. If you disable the use hypervisor assigned MAC addresses, the VM-Series firewall assigns each interface of a MAC address from its own pool. Because this causes the MAC addresses on each interface to differ, you must enable promiscuous mode (see Before deploying the OVA file, set up virtual standard switch(es) and virtual distributed switch(es) that you will need for the VM-Series firewall.) on the port group of the virtual switch to which the dataplane interfaces of the firewall are attached to allow the firewall to receive frames. If neither promiscuous mode nor hypervisor assigned MAC address is enabled, the firewall will not receive any traffic. This is because vSphere will not forward frames to a virtual machine when the destination MAC address of the frame does not match the vmNIC MAC address.
Data Plane Development Kit (DPDK) is enabled by default on VM-Series firewalls on ESXi. For more information about DPDK, see Enable DPDK on ESXi.
To achieve the best performance out of the VM-Series firewall, you can make the following adjustments to the host before deploying the VM-Series firewall. See Performance Tuning of the VM-Series for ESXi for more information.
Enable DPDK. DPDK allows the host to process packets faster by bypassing the Linux kernel. Instead, interactions with the NIC are performed using drivers and the DPDK libraries.
Enable SR-IOV. Single root I/O virtualization (SR-IOV) allows a single PCIe physical device under a single root port to appear to be multiple separate physical devices to the hypervisor or guest.
Do not configure a vSwitch on the physical port on which you enable SR-IOV. To communicate with the host or other virtual machines on the network, the VM-Series firewall must have exclusive access to the physical port and associated virtual functions (VFs) on that interface.
Enable multi-queue support for NICs. Multi-queue allows network performance to scale with the number of vCPUs and allows for parallel packet processing by creating multiple TX and RX queues.
Note:-
Do not use the VMware snapshots functionality on the VM-Series on ESXi. Snapshots can impact performance and result in intermittent and inconsistent packet loss.See VMWare’s best practice recommendation with using snapshots.
If you need configuration backups, use Panorama or Export named configuration snapshot from the firewall (Device > Set up > Operations). Using the Export named configuration snapshot exports the active configuration (running-config.xml) on the firewall and allows you to save it to any network location.
The VM-Series firewall functionality is very similar to the Palo Alto Networks hardware firewalls, but with the following limitations:
Dedicated CPU cores are recommended.
High Availability (HA) Link Monitoring is not supported on VM-Series firewalls on ESXi. Use Path Monitoring to verify connectivity to a target IP address or to the next hop IP address.
Up to 10 total ports can be configured; this is a VMware limitation. One port will be used for management traffic and up to 9 can be used for data traffic.
Only the vmxnet3 driver is supported.
Virtual systems are not supported.
vMotion of the VM-Series firewall is not supported. However, the VM-Series firewall can secure guest virtual machines that have migrated to a new destination host, if the source and destination hosts are members of all vSphere Distributed Switches that the guest virtual machine used for networking.
VLAN trunking must be enabled on the ESXi vSwitch port-groups that are connected to the interfaces (if configured in vwire mode) on the VM-Series firewall.
To use PCI devices with the VM-Series firewall on ESXi, memory mapped I/O (MMIO) must be below 4GB. You can disable MMIO above 4GB in your server’s BIOS. This is an ESXi limitation.
Register your VM-Series firewall and obtain the OVA file from the Palo Alto Networks Customer Support web site.
Note:- The OVA is downloaded as a zip archive that is expanded into three files: the .ovf extension is for the OVF descriptor file that contains all metadata about the package and its contents; the .mf extension is for the OVF manifest file that contains the SHA-1 digests of individual files in the package; and the .vmdk extension is for the virtual disk image file that contains the virtualized version of the firewall.
Before deploying the OVA file, set up virtual standard switch(es) and virtual distributed switch(es) that you will need for the VM-Series firewall.
If you are deploying the VM-Series firewall with Layer 3 interfaces, your firewall will use Hypervisor Assigned MAC Addresses by default. If you choose to disable the use of hypervisor assigned MAC address, you must configure (set to Accept) any virtual switch attached to the VM-Series firewall to allow the following modes:
Log in to vCenter from the vSphere Web Client. You can also go directly to the target ESXi host if needed.
From the vSphere client, select .
Browse to the OVA file that you downloaded and select the file and then click Next. Review the templates details window and then click Next again.
Name the VM-Series firewall instance and in the Inventory Location window, select a Data Center and Folder and click Next
Select an ESXi host for the VM-Series firewall and click Next.
Select the datastore to use for the VM-Series firewall and click Next ( Default virtual disk format is thick and you may change to Thin )
Select the networks to use
Review the details window, select the Power on after deployment check box and then click Next.
Access the console of the VM-Series firewall.
Enter the default username/password (admin/admin) to log in.
Enter configure to switch to configuration mode.
Configure the network access settings for the management interface. You should restrict access to the firewall and isolate the management network. Additionally, do not make the allowed network larger than necessary and never configure the allowed source as 0.0.0.0/0.
#set deviceconfig system type static #set device config system ip-address <Firewall-IP> netmask <netmask> default-gateway <gateway-IP> dns-setting servers primary <DNS-IP> #commit
Now you have to exit from configuration mode by entering exit
Open the Browse and type the IP you have assigned to the VM to access the console.
Enter the credentials
You are logged in to the PA firewall and you can start using it
Conclusion
Here we shared detailed information about the deployment of paloalto VM-Series edition and steps to follow for a successful deployment. Also what is the limitation and system requirements for a virtual edition with reference links have been added to it, you have to refer them before starting the deployment